DAIKIN – Heat pump system – ERLA011DV3 / EBBX11D9W

0,00

Out of stock

SKU: 1981 Category:

Description

Technical specifications:

EBBX11DF9W / ERLA11DAV3 EBBX16DF9W / ERLA14DAV3 EBBX16DF9W / ERLA16DAV3
Heating capacity Nom. kW 10.6 (1), 9.82 (2) 12.0 (1), 12.5 (2) 16.0 (1), 16.0 (2)
Cooling capacity Nom. kW 11.2 (3), 12.0 (4) 13.1 (3), 13.3 (4) 13.8 (3), 15.9 (4)
Absorbed power Heating Nom. kW 2.18 (1), 2.68 (2) 2.46 (1), 3.42 (2) 3.53 (1), 4.56 (2)
Cooling Nom. kW 3.43 (3), 2.52 (4) 4.32 (3), 2.86 (4) 4.68 (3), 3.82 (4)
COP 4.83 (1), 3.66 (2) 4.87 (1), 3.64 (2) 4.53 (1), 3.51 (2)
EER 3.26 (3), 4.75 (4) 3.02 (3), 4.66 (4) 2.94 (3), 4.16 (4)
Room heating Cond. Water outlet clim. averages 55 ° C General SCOP 3.27 3.26 3.35
Seasonal efficiency class Room heating A ++ A ++ A ++
ηs (Seasonal efficiency Room heating) % 128 128 131
Cond. Water outlet clim. averages 35 ° C General SCOP 4.72 4.68 4.68
ηs (Seasonal efficiency Room heating) % 186 184 184
Seasonal space heating efficiency class A +++ A +++ A +++
Note (1) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C) (1) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C) (1) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C)
(2) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 45 ° C (Dt = 5 ° C) (2) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 45 ° C (Dt = 5 ° C) (2) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 45 ° C (Dt = 5 ° C)
(3) – Cooling: EW 12 ° C; LW 7 ° C; outside temperature: 35 ° CDB (3) – Cooling: EW 12 ° C; LW 7 ° C; outside temperature: 35 ° CDB (3) – Cooling: EW 12 ° C; LW 7 ° C; outside temperature: 35 ° CDB
(4) – Cooling: EW 23 ° C; LW 18 ° C; outside temperature: 35 ° CDB (4) – Cooling: EW 23 ° C; LW 18 ° C; outside temperature: 35 ° CDB (4) – Cooling: EW 23 ° C; LW 18 ° C; outside temperature: 35 ° CDB
(5) – Complies with EN14825 (5) – Complies with EN14825 (5) – Complies with EN14825
(6) – Condition 1: cooling Ta 35 ° C – LWE 18 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C) (6) – Condition 1: cooling Ta 35 ° C – LWE 18 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C) (6) – Condition 1: cooling Ta 35 ° C – LWE 18 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C)
(7) – Condition 2: cooling Ta 35 ° C – LWE 7 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 45 ° C (DT = 5 ° C) (7) – Condition 2: cooling Ta 35 ° C – LWE 7 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 45 ° C (DT = 5 ° C) (7) – Condition 2: cooling Ta 35 ° C – LWE 7 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 45 ° C (DT = 5 ° C)
(8) – Measured with pressure drop of 10 kPa in the heating system at operating conditions of the leaving water of 47-55 ° C in an environment with an external temperature of 20 ° C. BS / BU 7 ° C / 6 °. (8) – Measured with pressure drop of 10 kPa in the heating system at operating conditions of the leaving water of 47-55 ° C in an environment with an external temperature of 20 ° C. BS / BU 7 ° C / 6 °. (8) – Measured with pressure drop of 10 kPa in the heating system at operating conditions of the leaving water of 47-55 ° C in an environment with an external temperature of 20 ° C. BS / BU 7 ° C / 6 °.