Technical specifications:
EBBX11DF9W / ERLA11DAV3 | EBBX16DF9W / ERLA14DAV3 | EBBX16DF9W / ERLA16DAV3 | |||||
---|---|---|---|---|---|---|---|
Heating capacity | Nom. | kW | 10.6 (1), 9.82 (2) | 12.0 (1), 12.5 (2) | 16.0 (1), 16.0 (2) | ||
Cooling capacity | Nom. | kW | 11.2 (3), 12.0 (4) | 13.1 (3), 13.3 (4) | 13.8 (3), 15.9 (4) | ||
Absorbed power | Heating | Nom. | kW | 2.18 (1), 2.68 (2) | 2.46 (1), 3.42 (2) | 3.53 (1), 4.56 (2) | |
Cooling | Nom. | kW | 3.43 (3), 2.52 (4) | 4.32 (3), 2.86 (4) | 4.68 (3), 3.82 (4) | ||
COP | 4.83 (1), 3.66 (2) | 4.87 (1), 3.64 (2) | 4.53 (1), 3.51 (2) | ||||
EER | 3.26 (3), 4.75 (4) | 3.02 (3), 4.66 (4) | 2.94 (3), 4.16 (4) | ||||
Room heating | Cond. Water outlet clim. averages 55 ° C | General | SCOP | 3.27 | 3.26 | 3.35 | |
Seasonal efficiency class Room heating | A ++ | A ++ | A ++ | ||||
ηs (Seasonal efficiency Room heating) | % | 128 | 128 | 131 | |||
Cond. Water outlet clim. averages 35 ° C | General | SCOP | 4.72 | 4.68 | 4.68 | ||
ηs (Seasonal efficiency Room heating) | % | 186 | 184 | 184 | |||
Seasonal space heating efficiency class | A +++ | A +++ | A +++ | ||||
Note | (1) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C) | (1) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C) | (1) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C) | ||||
(2) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 45 ° C (Dt = 5 ° C) | (2) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 45 ° C (Dt = 5 ° C) | (2) – State: Ta BS / BU 7 ° C / 6 ° C – LWC 45 ° C (Dt = 5 ° C) | |||||
(3) – Cooling: EW 12 ° C; LW 7 ° C; outside temperature: 35 ° CDB | (3) – Cooling: EW 12 ° C; LW 7 ° C; outside temperature: 35 ° CDB | (3) – Cooling: EW 12 ° C; LW 7 ° C; outside temperature: 35 ° CDB | |||||
(4) – Cooling: EW 23 ° C; LW 18 ° C; outside temperature: 35 ° CDB | (4) – Cooling: EW 23 ° C; LW 18 ° C; outside temperature: 35 ° CDB | (4) – Cooling: EW 23 ° C; LW 18 ° C; outside temperature: 35 ° CDB | |||||
(5) – Complies with EN14825 | (5) – Complies with EN14825 | (5) – Complies with EN14825 | |||||
(6) – Condition 1: cooling Ta 35 ° C – LWE 18 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C) | (6) – Condition 1: cooling Ta 35 ° C – LWE 18 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C) | (6) – Condition 1: cooling Ta 35 ° C – LWE 18 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 35 ° C (DT = 5 ° C) | |||||
(7) – Condition 2: cooling Ta 35 ° C – LWE 7 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 45 ° C (DT = 5 ° C) | (7) – Condition 2: cooling Ta 35 ° C – LWE 7 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 45 ° C (DT = 5 ° C) | (7) – Condition 2: cooling Ta 35 ° C – LWE 7 ° C (DT = 5 ° C); heating Ta DB / WB 7 ° C / 6 ° C – LWC 45 ° C (DT = 5 ° C) | |||||
(8) – Measured with pressure drop of 10 kPa in the heating system at operating conditions of the leaving water of 47-55 ° C in an environment with an external temperature of 20 ° C. BS / BU 7 ° C / 6 °. | (8) – Measured with pressure drop of 10 kPa in the heating system at operating conditions of the leaving water of 47-55 ° C in an environment with an external temperature of 20 ° C. BS / BU 7 ° C / 6 °. | (8) – Measured with pressure drop of 10 kPa in the heating system at operating conditions of the leaving water of 47-55 ° C in an environment with an external temperature of 20 ° C. BS / BU 7 ° C / 6 °. |